Funct. Mater. 2015; 22 (1): 144-148.

http://dx.doi.org/10.15407/fm22.01.144

Position-sensitive detector based on plastic scintillator for muon tomography

A.I.Ivanov, V.A.Tarasov, V.Y.Pedash

Institute for Scintillation Materials, STC ″Institute for Single Crystals″ National Academy of Sciences of Ukraine, 60 Lenin Ave., 61001 Kharkiv, Ukraine

Abstract: 

The analysis of the different models of a plastic position-sensitive detector construction for muon tomography is discussed. The key feature of the detectors is the ability of, a passive registration of ionizing radiation from the inspected object. The optimal configuration of the detector has been determined, and its main parameters in both modes of operation has been assesed.

Keywords: 
plastic position-sensitive detector, muon tomography.
References: 

1. C.L.Morris, C.C.Alexander, J.D.Bacon et al., Scie. & Global Security, 16, 37 (2008). http://dx.doi.org/10.1080/08929880802335758

2. A.A.Borisov, M.Y.Boholubsky, N.T.Bozhko et al., Preprint IFVE 2011-7, Protvino (2011).

3. L.J.Schultz, G.S.Blanpeid, N.Borozdin et al., IEEE Trans. Image Processing, 16, 1985 (2007). http://dx.doi.org/10.1109/TIP.2007.901239

4. S.Riggi, V.Antonuccio-Delogu, M.Bandieramonte et al., Nucl. Instrum. Meth. Phys. Res. A, 728, 59 (2013). http://dx.doi.org/10.1016/j.nima.2013.06.040

5. Woo Jin Jo, Hyun-Il Kim, Su Jung An et al., Nucl. Instrum. Meth. Phys. Res. A, 732, 568 (2013). http://dx.doi.org/10.1016/j.nima.2013.05.115

6. P.N.Zhmurin, V.N.Lebedev, V.D.Titskaya et al., Functional Materials, 21, 282 (2014). http://dx.doi.org/10.15407/fm21.03.282